From microphone to digital level
After you press Start and grant permission, the browser provides a live microphone stream. When AudioWorklet is available, it consumes the continuous mono digital stream and sums its energy into complete windows of approximately 125 milliseconds. Every frame in those windows contributes once; the interface updates when a window is complete. If the worklet cannot initialize, a compatible callback processor consumes complete audio blocks into the same windows. Only a browser without either processor uses the disclosed short-window snapshot fallback, which can miss brief events. For samples x₁ through xₙ, we calculate RMS = √(Σx² / n) and then dBFS = 20 × log10(RMS).
The Web Audio API provides these digital samples. Only sums, frame counts and derived levels are retained; audio blocks are not saved or sent over the network. They describe the signal reaching the browser. The API does not establish an acoustic calibration for the device microphone.
The raw digital silence floor is −120 dBFS. It prevents non-finite logarithms and keeps the interface usable. It is not a measured acoustic noise floor. The instrument has no A-weighting filter, and its readings must not be labeled dBA.
How Estimated dB is displayed
The main display uses Estimated dB = dBFS + base offset + manual adjustment. The default base offset is 94 dB. This default is a display mapping, not a calibrated sound-pressure reference.
Manual adjustment can add or subtract up to 30 dB from the current base offset. The displayed number is not clamped to a fixed range. Its accuracy still depends on the microphone, processing, and reference settings.
Level status and hearing guidance
The status beneath the main number describes the displayed level band, with practical advice about duration, distance and hearing protection. It does not identify a sound source. The chart’s 85 and 100 Estimated dB lines are visual caution references on this estimate’s scale, not measured dBA safety limits. The hearing guidance gives broad exposure context; it does not assess your actual exposure or start a personal safe-time countdown.
The live frequency spectrum
The analyser uses a 16,384-point FFT on the same microphone stream, independently of the approximately 125 ms level windows. Frequency bins are spaced by the actual sample rate divided by 16,384: 2.93 Hz at 48 kHz, with a 341 ms analysis window. The spectrum waits for a full window after Start. At 16 kHz, the window is about 1.02 seconds. A longer window improves low-frequency resolution but spreads fast changes over more time; FFT bin spacing is not a guarantee that two nearby tones can be separated.
We group positive-frequency bins into 32 logarithmic bands from 20 Hz to the lower of 20 kHz and the actual Nyquist limit. For display, 20–1,000 Hz uses 35% of a split logarithmic axis; 1,000 Hz to the actual upper limit uses 65%. All frequencies above 1,000 Hz share one logarithmic ratio, so 1k–2k, 5k–10k and 10k–20k have equal spacing. This expands high-frequency spacing without changing the bands, measured Hz or power. An upper limit at or below 1,000 Hz uses one logarithmic axis. Each bar sums the digital power in its band. The browser applies a periodic Blackman window and a normalized FFT; we compensate its mean squared window, U = 0.3046, and account for the negative-frequency half of real audio: Pband = (2 / U) × Σ10^(binDb/10), then Lband = 10 × log10(Pband). Smoothing is disabled. RMS 1 is the 0 dBFS reference; a full-scale peak sine has total RMS power of −3.01 dBFS.
A tone can spread across adjacent bands because of the window and band boundaries. Wider bands collect more broadband-noise power. Neither behavior identifies a voice or a source. The strongest-frequency marker is the center of the strongest individual FFT bin in range, not a voice fundamental or a sub-bin estimate. No display offset or A weighting is applied. These are digital band-power estimates, not calibrated SPL or dBA, and their window differs from the main reading.
DC, bins below 20 Hz and above the display range, and the Nyquist bin absent from the browser output are excluded. Digital silence uses a −120 dBFS calculation floor, while unresolved bands remain empty. The default plot displays −80 to 0 dBFS: bands at or below −80 dBFS have no visible column. This is a disclosed display limit, not a noise gate or a finding that the band contains no signal. “Show weaker signals” expands the plot to −120 dBFS, preserving the same underlying values and frequency positions. An input entirely below the default range is labeled as below the display range rather than as silence. Only the current derived frame is kept and cleared on Stop or interruption; no spectrum history or audio is exported. The calculation follows the Web Audio FFT definition and window-power normalization.
Statistics and recent history
Min and Max are the lowest and highest complete RMS-window display levels in the current session. The standard window is approximately 125 milliseconds, with its duration calculated from actual frame count and sample rate. Snapshot fallback uses its observed polling interval and is identified in Settings and reports. Max is not an instantaneous acoustic peak metric.
Average is calculated in the energy domain, with valid sample durations as weights: Lavg = 10 × log10(Σ(t × 10^(L/10)) / Σt). Directly averaging dB numbers would underestimate the contribution of louder intervals.
The chart keeps the latest 30 seconds of valid history. Session statistics can cover a longer period than the chart. Browser suspension and other observation gaps are not inserted as silent samples. Calibration changes reset statistics so readings on different scales cannot be mixed.
Reference alignment and relative baseline
Reference alignment takes a 10-second sample under a steady condition. You enter the reading from a reference instrument observing the same sound field. The new base offset is reference level − sampled raw energy-average level; the manual adjustment returns to zero.
The status is Reference aligned. This describes the action performed, not verification of the reference meter or an acoustic accuracy tolerance. Recheck after changing the microphone, gain, browser, or device settings. Follow the reference alignment guide.
A relative baseline observes a room's digital level without assigning an acoustic value. The quietness of an unknown room cannot supply a known sound-pressure reference, so a baseline does not create SPL calibration.
Browser processing and microphone release
We request capture with echo cancellation, noise suppression, and automatic gain control disabled. The actual settings depend on browser and hardware support. Where available, the tool reports whether processing remains enabled; an unsupported setting is not proof that the signal is unprocessed.
Stopping, leaving the page, or losing the input releases the microphone tracks and audio processing resources. Each fresh start uses one capture pipeline. The signal is not connected to speaker playback.
Local reports
A report contains the session time, valid sampled duration, Min/Average/Max, full-session overview, offset, and accuracy status. PNG creation and the print view run locally. Printing to PDF uses your browser or operating system's print facility. Reports contain no audio.
These calculations establish consistent digital arithmetic, not acoustic calibration. Read what can affect accuracy before using a result.